KYORITSU MODEL 3132A


Category: Insulation Tester

Quick Overview:

Tag: #Analogue Insulation / Continuity Testers 

Share: Messenger


Analogue Insulation / Continuity Tester
•Dust and drip proof construction. (designed to IEC 60529 IP54)
•Designed to meet IEC 61010-1 and IEC 61557 safety standard.
•1mA rated test current at the minimum resistance.
•200mA measuring current on continuity testing.
•Automatic discharge of circuit capacitance.
(Any charge stored in the circuit under test will be automatically discharged after testing.)
•Live circuit warning buzzer and neon lamp.
•Small and lightweight. Shock resistant new case material.
•AC voltmeter with linear, easy-to-read scale.
•Operates on AA, R6 × 6 dry batteries.
  • ACV
  • Resistance
  • 250V
  • 500V
  • 1000V
 

Insulation Resistance

Test voltage 250V/500V/1000V
Measuring ranges
(Mid-scale value)
100MΩ/200MΩ/400MΩ 
(1MΩ) (2MΩ) (4MΩ)
Output voltage on open circuit Rated test voltage+20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1 - 2mA DC
Accuracy 0.1 - 10MΩ/0.2 - 20MΩ/0.4 - 40MΩ
(Accuracy Guaranteed Ranges) ±5% of indicated value

Continuity

Measuring ranges
(Mid-scale value)
3Ω/500Ω
(1.5Ω) / (20Ω)
Output voltage on open circuit 4.1V DC approx.
Measuring current 210mA DC min.
Accuracy ±1.5% of scale length

AC Voltage

AC Voltage 0 - 600V AC
Accuracy ±5% of scale length

General

Safety Standard IEC 61010-1 CAT III 600V Pollution Degree 2
IEC 61010-2-031
IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Power source R6 (AA) (1.5V) × 6
Dimensions 106(L) × 160(W) × 72(D)mm
Weight 560g approx.
Included Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 6 
9121 (Shoulder Strap) 
Instruction Manual

Product Catalogue


Sorry, Currently No Video Uploaded.
Sorry, Currently No File Uploaded.

KYORITSU MODEL 3132A


Please Leave Your Product Enquiry Here. We will Get Back To You Soon.

Product Specifications

  • Product SKU : -
  • Weight (GRAM) : -
  • Dimension : -


Locate Us